WARNING - RISK OF ELECTRIC SHOCK. DISCONNECT
MAIN POWER AT FUSE OR CIRCUIT BREAKER
BEFORE INSTALLING OR SERVICING THE FIXTURE.
LED 5” RETROFIT TRIM INSTALLATION
INSTRUCTIONS - MODEL CER5741A
QUESTIONS? CALL TOLL
FREE 1-800-345-0542
ALL RIGHTS RESERVED COMMERCIAL ELECTRIC 2014
Please read carefully and save these instructions, as
you may need them at a later date.
GENERAL: All electrical connections must be in accordance with
local and National Electrical Code (N.E.C.) standards. If you are
unfamiliar with proper electrical wiring connections obtain the services
of a qualified electrician.
Remove the trim from the box and make sure that no parts are
missing by referencing the PARTS illustrations.
THIS RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT
OF A LED LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY CSA OR CANADIAN
AUTHORITIES HAVING JURISDICTION.
__________________________________________
WARNING- RISK OF FIRE OR ELECTRIC SHOCK
FOR USE WITH HOUSING MODELS: INCANDESCENT
HOUSINGS COMMERCIAL ELECTRIC HBR5ICAT, HBR5ICRAT,
HBR5, HBR5R; HALO H5T, H5RT, H5ICT, H5RICAT, H5RICAT;
CORDELIA X5LICAT, X5LICRAT; ELCO EL5ICA, EL5RICA;
LITHONIA L5, L5R; ELITE B5, B5R, B5IC, B5RIC. HALO LED
HOUSINGS H550ICAT, H550RICAT.
Do not alter, relocate, or remove wiring, lampholders, power supply,
or any other electrical component. Installation of the retrofit
assembly requires a person familiar with the construction and
operation of the luminaire’s electrical system and the hazard
involved. IF NOT QUALIFIED, DO NOT ATTEMPT
INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.
Do not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
To prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects.
____________________________
ASSEMBLY AND INSTALLATION
1. If the installed housing does not have TORSION SPRING SLOTS
or C-CLIPS (FIG. 5), then remove the SCREWS securing the
TORSION SPRINGS to the HEATSINK. Attach the FRICTION
BLADES (included) to the same location using the SCREWS that
were previously removed. (FIG. 7)
INCANDESCENT HOUSINGS
1. Unscrew the WING NUT inside the CAN to detach the SOCKET
BRACKET from the CAN. Disengage the SOCKET from the
SOCKET BRACKET. (FIG. 2)
2. Thread the SOCKET ADAPTER into the SOCKET. (FIG. 3)
3. Plug the FEMALE CONNECTOR of the RETROFIT TRIM onto the
MALE CONNECTOR of the SOCKET ADAPTER ASSEMBLY.
(FIG. 4)
4. If using TORSION SPRINGS, squeeze both TORSION SPRING
arms together and insert into the TORSION SPRING SLOTS (or
RECEIVER BRACKETS) of the CAN. (FIG. 5)
5. Tuck all wires into the CAN and carefully push the RETROFIT
TRIM into CAN. (NOTE: To provide enough room in shallow cans,
carefully position SOCKET ADAPTER and SOCKET adjacent to
the long side of the LED DRIVER prior to inserting the RETROFIT
TRIM into the CAN.) (FIG. 5)
LED HOUSINGS
1. Plug the FEMALE CONNECTOR of the RETROFIT TRIM onto the
MALE CONNECTOR of the HALO HOUSING. (FIG. 4)
2. If using TORSION SPRINGS, squeeze both TORSION SPRING
arms together and insert into the TORSION SPRING SLOTS (or
RECEIVER BRACKETS) of the CAN.
3. Tuck all wires into the CAN and carefully push the RETROFIT
TRIM into CAN. (FIG. 5)
FACEPLATE REPLACEMENT (OPTIONAL)
This product is designed to allow the user to easily replace the
magnetically attached DECORATIVE FACEPLATE of the RETROFIT
TRIM.
1. Pull off the FACEPLATE from the RETROFIT TRIM. (FIG. 6)
2. Attach the replacement FACEPLATE onto the RETROFIT TRIM.
(FIG. 6)
5 in. 7 in.
FIG. 2
FIG. 3
PARTS
SOCKET ADAPTER
ASSEMBLY
RETROFIT TRIM
COMPATIBLE HOUSING
DIMENSIONS
FIG. 4
FIG. 5
5 in.
FIG. 6
OR
REV 04-AUG-14
FIG. 7
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - 1-800-345-0542

WARNING - RISK OF ELECTRIC SHOCK. DISCONNECT MAIN POWER AT FUSE OR CIRCUIT BREAKER BEFORE INSTALLING OR SERVICING THE FIXTURE.LED 5” RETROFIT TRIM IN

Page 2 - 120V 60Hz

_______________________________FIVE-YEAR LIMITED WARRANTYCommercial Electricwarrants this product to be free fromdefects in material and workmanship

Page 3 - CER5741A

ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA. DESCONECTE EL SUMINISTRO ELÉCTRICO DE LA CAJA DE FUSIBLES O LOS INTERRUPTORES DE CIRCUITO ANTES DE INSTALAR

Page 4

TODOS LOS DERECHOS RESERVADOS. PROPIEDAD INTELECTUAL COMMERCIAL ELECTRIC 2014___________________________________REGULADOR DE INTENSIDAD DE LA LUZ Ren

Page 5 - 12,7 – 17,78 cm

AVERTISSEMENT – RISQUE DE DÉCHARGE ÉLECTRIQUE. COUPEZ LE COURANT AU NIVEAU DU DISJONCTEUR OU DE LA BOÎTE DE FUSIBLES AVANT D’INSTALLER OU D’EFFECTUE

Page 6

_____________________________GARANTIE LIMITÉE DE CINQ ANSCommercial Electricgarantit ce produit contre tout défaut dematériaux ou de fabrication pour